Foreign unconfigured good driver

Unconfigured bad drives cannot be have the foreign configuration imported until you mark the drive as unconfigured good. Lsi megaraid controller mr92404i how to rebuild a failed. The drives will then be listed as foreign unconfigured good as shown below. Megaraid cannot import foreign config cachecade too.

Graphic showing opening screen for megaraid storage managerir msm windows. Clearing is typically only a good idea if the raid is simply degradedonline, and only a single drive shows as foreign youd clear in this scenario because the drive in question no longer has accurate uptodate data for the raid set, and a. Driver licenses issued to foreign nationals whose presence in the united states is temporarily authorized under federal law, may not be renewed by mail per mca 615111. How to clear foreign state hard drive in t630 with. How to clear foreign state hard drive in t630 with perc h730 controller jump to solution i recently purchased a poweredge t630 server computer configured. By clicking accept, you understand that we use cookies to improve your experience on our website. At this point, the data on this disk drive is no longer. I having trouble clearing foreign config on new raid harddrives on isis 5000. Perc 6i foreign config on disk how to clear a disk. The idrac shows the state of the disks as foreign, when i do. You can search forum titles, topics, open questions, and answered questions. Raid offline 1 drive missing, 1 drive foreign dell community. It does not show though the foreign prefix so i cannot import the old configuration and recreate the missing raid1 array.

I did the sataiii6g firmware update and now my 600gb sata 3 hard drive says unconfigured on the marvell boot screen. On the next page, select an unconfigured drive, click on the properties radio. One of the pds shows missing though it has a foreign config and the other shows missing it is failed. Megacli cheatsheet erikimh just another linux admins blog. Virtual drive has all drive members listed as unconfigured bad.

Once they were all unconfigured good i was able to scan foreign. Currently, it needs to use the workaround to clear configuration and make use of the hdd if it is a foreign unconfigured bad status. I have not selected cancel because i dont want to eiminate possibility of recovering my data. When newly inserted drives are detected by the intel raid controller, and are displayed in either intel raid bios console. So at this point once we get a good 5th drive, i want to clear the foreign config on just the new 5 drives. Thinkserver rd430, thinkserver rd530, thinkserver rd630, thinkserver ts430, megaraid storage manager, webbios. A drive may change status to foreign unconfigured bad if it was removed by accident from the raid enclosure while the system was running and inserted back in. Megaraid controller no way to configure 20160526, 2. If the hard drive passthrough function is disabled jbod mode is set to disabled for the raid controller card, you can enable the passthrough function to set all hard drives in the unconfigured good state to jbod this operation does not change the hard drives that have been added to the raid array. I, unfortunately, had this happen when i had a drive fail in a raid 10, ended up pulling the wrong drive from the array stupid me, it was late and i was trying to replace the drive quick, forgot my cable started with 0 or 1, megaraid didnt and had this happen. In regards to the application for an international drivers license, the usa cannot issue these permits to foreign visitors. Once all the drives have been marked good, head back to the megaraid bios home page, then click on scan devices to initiate a rescan of the enclosures. To find out which states require the permit, you must research the dmv policies for that state.

Nov 23, 2011 perc 6i foreign config on disk how to clear a disk. Wikis apply the wisdom of crowds to generating information for users interested in a particular subject. The foreign import occurs only on disks that are in the unconfigured good state. Cisco vsm raid viewer general parameters adapter parameter an the parameter an where n is a number starting wi. Lsi megaraid attached storage webbios cant import foreign configuration. The foreign state indicates that the intel raid controller finds existing. How to import configuration from foreign unconfigured good in. I tried parted magic and it shows up but if i try to zero the drive the machine locks up. All hdds go into unconfigured good after swapping one hdd ucs yeopal, something really important you left out was the raid level you had configured, if you swapped hdds and the raid level was 5 your array is lost cause it only allows the failure of one disk.

Using the lsi megaraid configuration utility menu to create a bootable logical drive x86 this section describes how to use the lsi megaraid configuration utility menu in the bios setup utility to create a logical drive on an x86 system. Setting the hard drive state to jbod or unconfigured good. Clear foreign config on raid harddrives avid community. You can search all wikis, start a wiki, and view the wikis you own, the wikis you interact with as an editor or reader, and the wikis you follow. Once they were all unconfigured good i was able to scan foreign config, import all configs, apply the config, and test and view all of my data. The volume should be redetected, and the operating system should start up again. Cisco ucs servers raid guide lsi megaraid sas controller. I want to use the drive for a spare, but there is a previous configuration 2. If you were bringing over two drives in raid 1, and wanted to keep the raid 1 array intact, using import would be a good option. Workaround install msm megaraid storage manager, and then the hdd status can be recovered from foreign unconfigured bad to foreign unconfigured good in. Workaround install msm megaraid storage manager, and then the hdd status can be recovered from foreign unconfigured bad to foreign unconfigured good in msm. It does not give an option to get the main menu configuration page where i can possibly put the configured bad drive into a configured good state and reattempt to import the foreign configuration. Recently ive had to do extensive work with dell poweredge servers, and specifically dells that use the lsi megaraid controllers.

Jul 19, 2016 using lsi megaraid storage manager in windows to recover from unconfigured bad disks chris adams. Find answers to lsi megaraid controller mr92404i how to rebuild a failed hard drive from the expert community at experts exchange. If a drive is currently part of a redundant configuration and you want to use it in another configuration, you can use the megaraid storage manager commands to remove the drive from the first configuration and change the drive state to unconfigured good. I had already tried those, unfortunately, this didnt show any options to create virtual drives or jbod. If you just plug drives into the lsi, theyll show up as unconfigured good. These servers run freebsd and lsi makes a binary available for this operating system. Find answers to lsi megaraid controller mr92404i how to rebuild a failed hard drive from the expert community at experts exchange lsi megaraid controller mr92404i how to rebuild a failed hard drive solutions experts exchange. After entering the controller configuration utility it shows both drives old working one and newly replaced one as unconfigured good. Using lsi megaraid storage manager in windows to recover from unconfigured bad disks chris adams. Once they were all unconfigured good i was able to scan foreign config, import all configs. The hard drive changes to foreign state, as shown in figure 6170. Lenovo thinkserver rd330 software user s manual pdf download. You will need to have your foreign driver license and your passport while driving. It means it has detected some raid informations on it, and thus, considers it as a disk being part of an array that may be imported into current controller.

Smartmontools with megaraid controller thomaskrennwiki. Navigate to the drives menu option in the left pane, or hit and. A good try to ensure that you system is in a good shape and not has problems with aborted installation is to invoke. Foreign drives detected on the raid card boot may be flagged as below. Access the bios utility to set the drive to the unconfigured good state. Introduction megacli commands have presented a number of questions among our users for ciscos physical security. In safestore section import a foreign configuration after you create a security key, you can run a scan for a foreign configuration and import a locked configuration.

You should be good to go based on what you performed clearing the foreign config, recreating the vd with the right order. Active pdcpd cachepiprotection infosedself encrypting drivefrgnforeign. Lenovo thinkserver rd330 software users manual pdf. Select the make unconfigured good option and select go. Then select go to controller scan foreign configuration as shown below. Megaraid apr 04, 2017 if a drive is currently part of a redundant configuration and you want to use it in another configuration, you can use the megaraid storage manager commands to remove the drive from the first configuration and change the drive state to unconfigured good. For details, see importing or deleting a foreign configuration. This utility apparently also works on rebranded lsi cards from dell certain perc cards and other vendors. X3650 m4 hd server megaraid controller no way to configure. Locate makes the led flash on the drive, which works only if the drive is installed in a drive enclosure. Feb, 2016 unconfigured bad drives cannot be have the foreign configuration imported until you mark the drive as unconfigured good. Ibm director is unable to clear foreign configuration of hdd. Enclid252 slotid4 state changed to unconfigured good.

Lsi megaraid recreate missing raid 1 array server fault. Lsi megaraid foreign configuration import or clear. Megaraid management applications through a driver configuration protocol dcp. Restoring a hard drive in frnbad state huawei v5 server raid. The right pane shows the virtual drive properties of the foreign configuration. After the foreign configuration is cleared, the hard drive changes to unconfigured good state. When retyping our costum password it shows up an error. Get the best of sth delivered weekly to your inbox. Disks in the failed or offline state cannot be imported. When driving in the united states with a foreign license is it strongly advised to have all your papers with you at all times. Restoring a hard drive in frnbad state huawei v2 and v3. After the foreign configuration is imported, the hard drive changes to online state. Recovering a failed lsi or intel raid array stone computers.

From the select operation menu, select initialize drive and then press enter. Fixing a drive labeled foreign by a lsi avago sas controller. Raid offline 1 drive missing, 1 drive foreign inherited a raid 5 configuration i know, no good to start, with 6 pds and 4 vds. Repeat for all of the drives listed as unconfigured bad. Exit the ctrlr raid bios and let the system restart. On the bottomright area of the raid bios screen, select the replace missing pd option and select go. For years now this question has come up in various forms so today it is time to show the easy fix. Repeat steps 3 and 4 for every unconfigured bad drive. Now we have orientated ourselves go back to the virtual disk management page, highlight the controller at the top of the screen and press f2 to list the available operations. The next tab, physical disk management shows the new foreign disk in slot 0.

Webbios configuration utility webbios cu main screen options drive status such as online or unconfigured good. Creating a raid 0, 1, 5 or 6 through the lsi web bios. In the foreign unconfigured good window, use the up arrow key or the down arrow key to select and then press enter. After these two options have been selected, the option to rebuild the raid array is available. Our 20101129161955547 included lsi 9260 megaraid adapters.

However, i have got a little further, previously i had been clearing configuration in the controller as this was the only option available. Do you have a driving licence that was issued in one of the countries of the european union eu or european free trade association efta and do you live in. Manually making the drives unconfigured good results in the drive status moving from frnbad to foreign. Iam also not going to ask why idrac reported the disks as foreign even though the controller through perccli said unconfigured good or why dell person could not give me this advice. If a hot spare drive is replaced, the new hot spare drive will go to the unconfigured good, unconfigured bad, jbod, or foreign configuration state. Most renewals must be conducted in person at an exam station. Attention after you perform this procedure, all data on that drive is lost. Information you need about driver licenses, commercial licenses, the graduated driver licensing program for teen drivers, and information about tickets and. Assuming the new disk is inserted it will be displayed as unconfigured good in the drive group. Here is one from the mailbag about how to fix a drive labeled as foreign by a lsi avago sas controller when it is inserted into a system. Did a bit more digging and had a look through the docs and the foreign config on the drives with megacli. A foreign configuration is a storage configuration that already exists on a set of drives that you install in a server. View and download lenovo thinkserver rd330 software user s manual online. This often has a good chance of bringing the raid back online.

Their state may show as foreign unconfigured good, or foreign unconfigured bad. Somewhat counterintuitively when managing one newly added foreign drive one needs to click on the controller not the drive in msm. Here is an attempt to explain thier meaning and uses. Clicking through the bios settinsg for the storae just shows the disks installed as unconfigured good but with no option to change anything.

Click the respective hard drive that is marked unconfigured bad. This should then prompt you with any foreign configurations detected, which you can then import. I connected the drive to an intel sata port and the drive. The last tab shows the foreign configuration as well and the current active configuration. Some drives may show up with unconfigured bad status. Doing a scan devices did not find any foreign configuration for me to import. It shows all my drives in online state except one which is colored blue and in a unconfigured bad state. Foreign configuration import screen follow these steps to import or clear a.

Raid array rebuild doesnt start on removal and reinsertion. The lsi intention is for individual drives to be aggregated into virtual drives, such as that virtual drive 0 which is a raid1 of two ssds, which is a common config here for our esxi hosts. Click clear to clear the foreign configuration and reuse the drives for another virtual drive. Using the lsi megaraid configuration utility menu to create a.

It may also change the status if a drive from another system was inserted to that slot. From the select operation menu, select initialize drive. The controller will now recognise the disk as being a foreign one. In addition to this conventional way the smartmontools also support querying smart attributes of hard drivesssds, which are connected to an lsi raid controller. There is no option to enter into the web setup utility.

I recently gained my first experience with the infamous megacli command line configuration utility for lsibased raid controllers. Anyone who has ever had to work with the lsi raid controllers knows that the megacli provided by lsi is the most cryptic command line utility in existence. Many states allow driving in the usa with a foreign license, as long as the license is valid. Cisco ucs manager storage management guide, release 4. Urgent lsi megaraid how to insert multiple drives with. How can i set it to unconfigured good without shutting down. Problem with foreign disk cfg on serveraid m5110e x3650 m4. Using lsi megaraid storage manager in windows to recover from.

At this point, msm will scan drives on the controller and say how many foreign drives it found. If this is the case, make sure to reinsert the correct driver to the correct slot. The disk state of a physical disk can change from the time the foreign configuration is scanned to when the actual import occurs. How to import configuration from foreign unconfigured good in lsi megaraid configuration utility. Cisco ucsm will raise a virtual drive mismatch or virtual drive member mismatch fault because the hot spare drive is in a. Using lsi megaraid storage manager in windows to recover. The disk drive status changes to unconfigured good. Browse through our collection of articles, user guides and faqs. How to import configuration from foreign unconfigured good in lsi megaraid configuration utility 20191001, 15. During controller initialization in post, hit to enter the megaraid bios.